+49 (0)33704 964-0
Deutsch
English
  • Start
  • About us
  • Product Overview
    • Gas cylinders with accessories
      • Technical characteristics
      • Liquid gas cylinders
      • Carrying / transfer racks
      • Bottle couplings
      • Label according to ADR
    • Liquid gas fittings
      • Technical characteristics
      • Gas regulator
      • Hose rupture protection
      • Gas regulator with hose rupture protection
      • Test set
      • Distributors
      • Pipe fittings
      • Accessories
    • Gas hoses
      • Integrated gas hoses
      • Individual parts for gas hoses
      • High pressure hose line
      • Twin hose lines
    • Soldering and shrinking tools
      • Technical characteristics
      • Handles
      • Soldering iron inserts
      • Copper tips
      • Solder inserts and shrink inserts
      • Soldering torch and shrinking torch
      • Economy handle and inserts
      • Transport boxes
      • Compilation
    • Handheld construction torch
      • Technical characteristics
      • Building hand burner BHB
      • Individual parts to combine
      • Hot air burner
      • AFG 1 flame treatment unit
      • AFG 2 flame treatment unit
    • Gas burner
      • Technical characteristics
      • Pilot burner
      • Jet burner
      • Cooker Burner
      • Lateral burner
      • Ring burners
      • Oval burner
      • Gas burner accessories
      • Nozzle table
    • Bitumen cooker
      • Bitumen cooker - Accessories
      • Bitumen cooker - Set
    • Ignition, safety and control devices
      • Regulating and shut-off valves
      • Electrodes
      • Temperature controller
      • Mechanical temperature controls
      • Valve with main gas lock
      • Ignition cable
      • Lighter
      • Electronic flame monitoring
      • Thermocouples
      • Solenoid valves
      • Quick-acting switching valve
      • Plug connector
  • Contact
  • Online shop

Building hand burner BHB

We are your complete supplier
for liquid gas fittings and burners
  • Gas cylinders with accessories
    • Technical characteristics
    • Liquid gas cylinders
    • Carrying / transfer racks
    • Bottle couplings
    • Label according to ADR
  • Liquid gas fittings
    • Technical characteristics
    • Gas regulator
    • Hose rupture protection
    • Gas regulator with hose rupture protection
    • Test set
    • Distributors
    • Pipe fittings
    • Accessories
  • Gas hoses
    • Integrated gas hoses
    • Individual parts for gas hoses
    • High pressure hose line
    • Twin hose lines
  • Soldering and shrinking tools
    • Technical characteristics
    • Handles
    • Soldering iron inserts
    • Copper tips
    • Solder inserts and shrink inserts
    • Soldering torch and shrinking torch
    • Economy handle and inserts
    • Transport boxes
    • Compilation
  • Handheld construction torch
    • Technical characteristics
    • Building hand burner BHB
    • Individual parts to combine
    • Hot air burner
    • AFG 1 flame treatment unit
    • AFG 2 flame treatment unit
  • Gas burner
    • Technical characteristics
    • Pilot burner
    • Jet burner
    • Cooker Burner
    • Lateral burner
    • Ring burners
    • Oval burner
    • Gas burner accessories
    • Nozzle table
  • Bitumen cooker
    • Bitumen cooker - Accessories
    • Bitumen cooker - Set
  • Ignition, safety and control devices
    • Regulating and shut-off valves
    • Electrodes
    • Temperature controller
    • Mechanical temperature controls
    • Valve with main gas lock
    • Ignition cable
    • Lighter
    • Electronic flame monitoring
    • Thermocouples
    • Solenoid valves
    • Quick-acting switching valve
    • Plug connector

Building hand burner BHB

Hand torch for drying, laying roofing membranes, thawing and scarfing

Series 51

  • Gas inlet G3/8LHa
  • Burner hood Ø 40 mm
  • Extension 250 mm
  • Power from 27 to 45 kW
    (from 1.5 bar to 4.0 bar)
Articleø hood in mmLength in mmOrder no.

Construction hand torch G3/8LHa 40-250

40

570

5142

LoremLorem
  • Ø burner hood 40, 50 and 60 mm
  • Extension 600 mm
  • Power from 27 to 133 kW
    (from 1.5 bar to 4.0 bar and from burner hood 40 to 60)
Articleø hood in mmLength in mmOrder no.

Construction hand torch G3/8LHa 40-600

40

630

5146

Construction hand torch G3/8LHa 50-600506605156
Construction hand torch G3/8LHa 60-600607305166
Construction hand torch G3/8LHa 60-600 PZ (w/o fig.)607305167
LoremLorem
(Subject to technical changes)

Performance and consumption overview

PressureConsumptionPower

Hood 40

1.5 bar

2.2 kg/h

27 kW


2.5 bar

2.8 kg/h

35 kW


4.0 bar

3.5 kg/h

45 kW

Hood 50

1.5 bar

4.0 kg/h

50 kW


2.5 bar

5.2 kg/h

65 kW


4.0 bar

6.5 kg/h

83 kW

Hood 60

1.5 bar

6.3 kg/h

80 kW


2.5 bar

8.2 kg/h

105 kW


4.0 bar

10.0 kg/h

133 kW

LoremLorem
1. function
The propane flows via the economy handle to the main shut-off valve. The valve shuts off the gas supply. When the valve is opened, a certain amount of gas flows through the set bypass. The bypass opening adjustment screw is located just upstream of the main shutoff valve and is sealed in its setting. It releases the gas path for the economy flame. The power flame is released by depressing the lever located below the main shutoff valve. The desired output can be set by depressing the power flame lever and adjusting the main shut-off valve. For safe storage of the burner, there is a stand on the extension tube which allows the burner to be stored in such a way that the pilot flame does not cause any danger.
2. start-up
  1. Connect the regulator with integrated hose rupture protection (RS) to the gas cylinder valve. (The connected load depends on the consumption of the burner) Connect burner inlet = G3/8LH (left-hand thread) with a high-pressure hose 6.3x5 (pressure class 30) to the RS (gas-tight).
  2. Open the cylinder valve
  3. Press the start button of the RS
  4. Open the economy valve completely
  5. Ignite propane at the burner head
  6. Press pilot lever = working flame
  7. Set the desired output with the main shut-off valve (propane quantity)
3. decommissioning
  1. Close the main shut-off valve on the burner handle.
  2. Close gas cylinder valve
  3. Vent the propane hose
4. technical guidelines
ISO 9012 BGV D1 BGV D34 BGV D16 GPSG
5. maintenance
The sealing washer in the screw connection on the inlet side of the RS must be checked for wear and the filter retaining screw must be checked for dirt (see also instructions for regulator and hose rupture protection).

Unauthorised repairs and interventions are not permitted.

Only an expert is allowed to change the gas quantity for the flame clamp adjustment. The adjusting screw must be sealed again after changes.
6. Single parts
ArticleOrder no.

BHB Burner handle G3/8LHa

5403

Extension 250

5412

Extension 350

5413

Extension 600

5416

Storage foot

5443

Burner head 40

5541

Burner head 50

5551

Brennerkopf 60

5561

Bedienungsanleitung

5100.0.99

Lorem
Do you need help or advice?
This is how you can reach us.
The fields marked with * are mandatory.
Submit form
Borrmann Brenner Berlin GmbH
OT Schöbendorf, Dämmchen 30 15837 Baruth / Mark Germany
+49 (0)33704 964-0
  • Sitemap
  • General Terms
  • Privacy Information
  • Imprint
Borrmann Brenner Berlin GmbH
OT Schöbendorf, Dämmchen 30 15837 Baruth / Mark Germany
+49 (0)33704 964-0